PH Meter

From Milk The Funk Wiki
Revision as of 11:06, 30 April 2015 by DanABA (talk | contribs)
Jump to: navigation, search

A pH Meter is not only considered by some to be an essential tool for all grain homebrewing and commercial brewing, but is also a very useful tool to have for making sour beer. For examples of when an accurate pH reading is useful in the sour brewing process, see the Mixed Fermentation, Sour Worting, and Lactobacillus pages.

Recommend pH Meters

High End pH Meters

Higher end pH meters recommended by our members and others.

Budget pH Meters

pH meters can range from $30 to $500+. The problem with many of the cheaper pH meters is that their reliability and longevity are often questionable [3]. Commonly, two pH meters are recommended by trustworthy sources (AJ Delange and Kai Troester).

Hach Pocket Pro+ pH Tester with Replaceable Sensor.

 
Hach Pocket Pro+

Features:

  • This pH meter is recommended by AJ Delange [3][4].
  • Does not require storage solution (there is an o-ring seal on the cap, which only needs to have a few drops of distilled water in it).
  • Replaceable sensor.
  • Stability [3].
  • 2 Buffer calibration.
  • Electrode longevity [3].
  • Junction resistant to fouling by sugars, proteins [3].
  • Lets the user decide when to accept a buffer calibration reading [3].
  • ATC [3].
  • Automatic buffer recognition [3].

Disadvantages:

  • Despite having an automatic calibration message, this pH still often needs to be calibrated before each brew day [3].

Milwaukee MW102 pH/Temp Meter (updated/upgraded from SM101 and MW101).

 
Milwaukee MW102

Features:

Disadvantages:

Buffer Solution

Buffer solution will be required to calibrate a pH meter. In general, it is recommended that a pH meter have a 2 point calibration method, which requires 4.0 buffer solution and 7.0 buffer solution. Many buffer solutions for pH meter calibration can be found on Amazon or other retailers.

Testing the Probe

The probes on pH meters generally have a limited life, depending on the quality of the unit. Milwakuee Instruments describes the following method for testing the life of the probe:

"A simple test can be performed using Windex glass cleaner with ammonia and white distilled vinegar. The procedure is as follows: Turn your meter or tester on and place the probe in white distilled vinegar which is acidic (2.4ph) and the reading will be from 2.3 to 2.5 but must be below 3.0 then go to the Windex with ammonia which is alkaline. Your display should move very quickly up the scale to 10.5 – 11.2 but must go above 10.0. If the probe slowly moves up the scale then it is time to consider replacing it. If it does not go below 3.0 pH in vinegar and/or above the 10.0 pH in Windex then probe is dead." [8]